Please use this identifier to cite or link to this item: http://repositorio.ufgd.edu.br/jspui/handle/prefix/5407
metadata.dc.type: Trabalho de Conclusão de Curso
Title: Avaliação do nível de pressão sonora emitido pelo túnel de vento aa- tvsh1 em um ambiente parcialmente fechado
Other Titles: Assessment of the sound pressure level emitted by the aa-tvsh1 wind tunnel in a partially closed environment
metadata.dc.creator: Fidelis, Paulo
metadata.dc.contributor.advisor1: Moreira, Bruno Arantes
metadata.dc.contributor.referee1: Pollnow, Edilson Nunes
metadata.dc.contributor.referee2: Gregolin, Rafael Ferreira
metadata.dc.description.resumo: A preocupação com a saúde dos colaboradores no ambiente de trabalho teve uma evolução durante o século XVIII e com o passar dos séculos foi se aperfeiçoando por meios de leis e normas regulamentadoras. Este estudo tem como objetivo avaliar o nível de pressão sonora emitido pelo túnel de vento AA- TVSH1 de circuito aberto, instalado em um laboratório localizado na Universidade Federal Da Grande Dourados. Os experimentos foram realizados com o auxílio de um decibelímetro, que permitiu a obtenção de medidas do ruído do equipamento em diferentes posições e rotações. O estudo foi baseado na norma NBR ABNT 10152: 2007, bem como, na Norma Regulamentadora n° 15 (NR- 15) levando em consideração os limites impostos para exposição ao ruído em ambientes internos. Com os resultados obtidos foi possível entender quais posições no laboratório a emissão de ruído era mais intensa, assim como, qual o tempo limite de exposição ao ruído um indivíduo poderia permanecer no ambiente conforme estabelecido pelo anexo 1 da NR -15. Por fim, foi possível propor uma solução para atenuar a exposição ao ruído na posição onde o operador do equipamento permanece maior tempo exposto.
Abstract: The concern with the health of employees in the work environment evolved during the 18th century and over the centuries it was improved through laws and regulatory standards. This study aims to evaluate the sound pressure level emitted by the open circuit AA-TVSH1 wind tunnel, installed in a laboratory located at Universidade Federal Da Grande Dourados. The experiments were carried out with the aid of a decibel meter, which allowed obtaining measurements of the equipment noise in different positions and rotations. The study was based on the NBR ABNT 10152: 2007 standard, as well as on the Regulatory Standard nº. 15 (NR15) taking into account the limits imposed for exposure to noise in indoor environments. With the results obtained, it was possible to understand which positions in the laboratory the noise emission was more intense, as well as, what the limit time of exposure to noise an individual could remain in the environment as established by annex 1 of NR -15. Finally, it was possible to propose a solution to attenuate noise exposure in the position where the equipment operator remains exposed for a longer time.
Keywords: Ruído
Noise
Túnel de vento
Wind tunnels
Decibelímetro
Decibel meter
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
metadata.dc.language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal da Grande Dourados
metadata.dc.publisher.initials: UFGD
metadata.dc.publisher.department: Faculdade de Engenharia
Citation: FIDELIS, Paulo. Avaliação do nível de pressão sonora emitido pelo túnel de vento aa- tvsh1 em um ambiente parcialmente fechado. 2022. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Mecânica) - Faculdade de Engenharia, Universidade Federal da Grande Dourados, Dourados, MS, 2022.
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.ufgd.edu.br/jspui/handle/prefix/5407
Issue Date: 21-Jun-2022
Appears in Collections:Engenharia Mecânica

Files in This Item:
File Description SizeFormat 
PauloFidelis.pdf3,49 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.